AOS-1MD Ozone Calibration Chart

Column on left side of chart are the flow rate settings on the oxygen regulator or flow meter.

Numbers 5 through 100 percent are the variable control settings which raises or lowers the output in gamma.

Range Selector 1 Low

LPM cc/min 5% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
1/32
1/16
1/8
1/4
1/2
3/4
1
31
62
125
250
500
750
1000
63
46
28.5
14.5
8.8
6.3
4.8
63.6
47.6
29
15
8.9
6.6
5.2
68.6
52.5
31.5
16.3
9.3
7.3
5.5
76
58.4
34.5
18.5
10.2
8.2
6
80
62.4
37.8
21
11.5
9.2
6.6
84.5
69.5
43
23.5
12.7
10.3
7.2
85
79.5
51.5
27.6
15.3
12
8.8
100
87
59.8
32.7
18.3
14.2
10.7
108
95
67.7
41.5
23.2
18.1
13.6
107
106
77.8
47.7
28
21.4
16.6
112
115
86.8
56.5
32.7
26.8
20.5

Range Selector 2

LPM cc/min 5% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
1/32
1/16
1/8
1/4
1/2
3/4
1
31
62
125
250
500
750
1000
79.6
60.4
37.3
21.2
11.8
8.1
5.9
81.4
60.8
37.7
21.5
12
8.3
6.1
87
63.4
39.7
22.5
12.5
8.8
6.3
93
68
43
24.2
13.2
9.5
6.9
97.6
73
47.5
26.3
14.3
10.3
7.5
101.2
80.5
51.6
29
15.5
11.6
8.5
107
88.5
60.3
34.5
17.5
13.4
10
114
94.6
68.2
39.3
21.4
15.7
11.5
121.5
103.6
76
46.5
26.3
20.4
15
124.6
111
84.7
54
31.6
23.4
18
127
118
97
64.6
38.3
29.3
22.5

Range Selector 3 Medium

LPM cc/min 5% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
1/32
1/16
1/8
1/4
1/2
3/4
1
31
62
125
250
500
750
1000
103
79
49.5
27
15.5
11
8.5
104
80
50.7
27.7
15.6
11.5
8.7
107
83
53.9
28.5
16.3
12
9.1
110
86.5
57.2
31
17.5
13
9.8
112
91
61.3
34.4
19
14.2
10.6
114.5
95
67
37.5
21.2
15.5
11.7
117
100.8
73
43
24.6
18.3
13.8
118
106.5
78
46.5
27.5
20.2
15.3
120
111.5
85
53
31.2
23.6
18
123.5
117
96
62.5
38.2
27.8
21
127
123.5
105
73.8
44.7
34.8
26.7

Range Selector 4

LPM cc/min 5% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
1/32
1/16
1/8
1/4
1/2
3/4
1
31
62
125
250
500
750
1000
113
90
59.3
34.9
19.3
12.6
10.7
113.7
91.5
59.6
35.3
19.4
12.9
11
115
94
62.4
36.6
20
13.6
11.5
116.5
97
66
39
22
15
12.2
117
100
70
42
23.5
16.6
13.8
118.6
103.5
73.2
45.5
25.9
18
14.8
120.5
107.6
79
50.5
28.8
20.3
16.3
121
111.5
85.3
55
32
23
18.3
122.3
117
94
62.6
37
27.2
21.6
125.5
122
103.9
72.5
43
33.5
25.3
128
126
114
83.3
52.3
41
31.7

Range Selector 5

LPM cc/min 5% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
1/32
1/16
1/8
1/4
1/2
3/4
1
31
62
125
250
500
750
1000
103.5
96
69
40
21.8
15.9
13
104
96
69.5
40.8
21.5
16
13.6
105.6
97.5
71.9
42.6
22.5
16.8
14
106.6
99.5
74.8
45
23.5
18
15
108.5
101
78.5
47.4
26.5
19.4
16
111.4
103.5
82.5
51
28.8
21
17.5
112.7
106
87.3
55.7
31.9
24
19
113.8
108.5
92
60
35
26.5
22
115
112.4
100
65.5
40.7
31.8
26
119
116
108
76.5
48
37.5
30
127
120
115.5
88
57
46
36

Range Selector 6 High

LPM cc/min 5% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
1/32
1/16
1/8
1/4
1/2
3/4
1
31
62
125
250
500
750
1000
110
100
75.6
45.6
26
19.5
15.3
110
101
76.6
46.4
26.3
19.9
15.5
110.8
101.2
78.6
48
27.5
20.6
16.2
112.2
103
81.5
51
29.3
22.1
17
114
104.5
84.3
53.5
31
23.5
18.4
115.5
106
88.7
56.7
33.3
25.4
19.8
116.6
108.3
94
61.8
36.9
28
21.9
116.3
110.4
98.5
66
40.5
31.4
24.2
118.4
114.5
106
75
47
36.5
28.7
120.8
118.7
112.3
83
53
42.5
33.2
123
122
118.6
93.5
61.5
48.5
38.1

Important Notes: When medical ozone concentration factors are given by various manufactures the following will reduce your confusion: 1 ug/ml = 1 mg/l = 1 g/m3 = 1 gamma. Also, 1 ml is = to 1 cc. 1 mcg/ml (microgram per milliliter) is equal to 1 ug/ml.

For instance, the output for the AOS-1MD at 1/2 liter/min flow with the range selector 6 setting and the variable control (VC) set at 100 percent, the output equals 61.5ug/cc = 61.5ug/ml = 61.5mg/l = 61.5g/m3 = 61.5 gamma.

Factors that can influence the outputs are elevation, flow rate, humidity, pressure, temperature, voltage or the quality of oxygen being used. There can also be a variance of outputs between different brands of oxygen regulators and flow meters.